Series 16H

The Series 16H is a commercial, cast-iron, gas-fired, hot-water boiler with thermal efficiency ratings of up to 81%. The Series 16H is designed for use with a conventional chimney. The boiler is packaged with an electronic ignition system for use with natural gas.

 

Description

The Series 16H is a commercial, cast-iron, gas-fired, hot-water boiler with thermal efficiency ratings of up to 81%. The Series 16H is designed for use with a conventional chimney. The boiler is packaged with an electronic ignition system for use with natural gas. The Series 16H is available in 4 sizes, with firing rates from 340 to 505 MBH, and is designed for multiple boilers to be piped together for larger installations.

The Series 16 is shipped as a semi-packaged boiler with the boiler sections, base, and flue collector preassembled; final assembly is then easily completed in the field. Its compact size allows for smooth transport to the install location, easily fitting through doorways.

 

Download Brochure

 

Series_16H-Literature

 

 

Velocity Boiler Works   Warranty Crown Boiler 

 

 

Product Brief

 

Type:Commercial
Heat Exchanger:Cast Iron
Fuel:Natural Gas
Input:350 to 505 MBH
Combustion Efficiency81.0%
Venting:Atmostpheric
Ignition:Electronic
Trim:Water
Domestic Water:N/A
Burner:N/A
Configuration:Semi-packaged
Notes:Optional base available for installation on a combustible floor.
Can be piped together for larger installations

 

 

Product Ratings

 

BOILER MODEL NO.INPUT
(MBH)
HEATING CAPACITY
(MBH)
AHRI NET RATING
(MBH)
THERMAL EFFICIENCY
(%)
WATER CONTENT
(GAL.)
APPROX. SHIPPING
WEIGHT
(LBS)
16H-34034027523981.015.9870
16H-41041032828580.117.9950
16H-46046037032280.419.91040
16H-50550540635380.521.91140
1. Not available for use in elevations above 2,000 ft.
2. The Net Water Ratings are based on a piping and pickup allowance of 1.15.
3. Maximum allowable working pressure is 50 PSI.
4. The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc.

 

 

Product Dimensions

 

MODEL NUMBERDIMENSIONS (INCHES)
ABCDE
16H-34027-1/213-3/4827-13/1618
16H-41031-1/415-5/8930-13/1620
16H-4603517-1/21033-1/222
16H-50538-3/419-3/81033-1/222
1. Not for direct installation on combustible flooring. A heat shield is required and available for installation on combustible floors and on concrete.
2. External draft hood supplied – may not be cut or altered.

series 16h drawing

 

 