Phantom Combi II

The Phantom Combi II is one of our newest products, and the first to feature Phantom Adaptive Technology! This is a gas fired, stainless steel, combi boiler with:

  • Field Convertible to LP – No conversion kit required
  • Rate based temperature reset – No outdoor sensor required
  • Simple start up

 

Category: Tag:
Brand: Velocity Boiler Works

Description

The Phantom Combi II is one of our newest products, and the first to feature Phantom Adaptive Technology! This is a gas fired, stainless steel, combi boiler with:

  • Field Convertible to LP – No conversion kit required
  • Rate based temperature reset – No outdoor sensor required
  • Simple start up

It is an energy efficient boiler with 95% AFUE that can not only heat a home, but also provide domestic hot water all from one boiler.

 

This brief video will introduce you to the Phantom Combi II and its features. 

 

 

 

Download Brochure

 

CVB-Phantom-Combi-II-Sheet-nc-PF-July-21

 

 

 Energy Star   Velocity Boiler Works

 

 

Product Brief

 

 

Type:Residential
Heat Exchanger:Stainless Steel
Fuel:Gas Fired (Natural Gas or LP)
Heating Input:13.6-120 MBH
Domestic Hot Water Input:136 MBH
Efficiency (AFUE)95%
Venting:Direct Vent
Ignition:Direct Spark
Trim:Water
Domestic Water:Included
Burner:Modulating with 10:1 turndown ratio
Configuration:Packaged
Notes:Low Loss Header included
2″ venting standard
5-year parts warranty

 

 

Product Ratings

 

 

Space Heating Ratings Domestic Hot Water (DHW) Ratings 1
Model NumberInput (MBH)
Min-Max
Heating Capacity,
MBH
Net AHRI Water,
MBH3
Energy StarAFUE, %Input (MBH)
Min-Max2
Max Draw GPMMin.4Approx. Shipping Weight (lbs)
70°F Rise77°F Rise90°F Rise
Combi Model PHNTM2136C13.6-1201129795.013.6-1363.73.42.90.5112
Notes:
  1. DHW ratings are not AHRI certified.
  2. Input and DHW draw limits for elevations up to 2,000 ft. with min vent length. See Installation Manual for derate at max vent length.
  3. Net AHRI Water Ratings shown are based on a piping and pickup allowance of 1.15. The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent operation, extensive piping systems, etc.
  4. Min DHW flow rate required through boiler to initiate DHW demand. Higher flow rate through fixture may be required due to mixing at tempering valve and/or fixture itself.
  5. Not for installation at altitudes above 2,000 feet.

 

 

Product Dimensions

 

MODEL NUMBERDEPTH (INCHES)HEIGHT (INCHES)WIDTH (INCHES)
PHNTM2136C16-5/829-7/818

 

CONNECTION SIZE
SUPPLY/RETURN1-1/4″ MPT
DHW3/4″ MPT
GAS1/2″ MPT
VENT2″ STD (3″ w/increaser)

 

 

 

 

Related Documents

 

Phantom_Combi_II_PAT_Installation_Manual

CVB-Phantom-Combi-II-Sheet-nc-PF-July-21

 

Reviews

There are no reviews yet.