Kingston (KSZ)

The Kingston (KSZ) Series boiler is an installer-ready, residential, cast-iron, oil-fired, steam boiler. The Kingston is designed for installation with a standard chimney. The Kingston is available in heating capacities from 79 to 235 MBH. This boiler is available in a semi-packaged ‘Shorty’ version. The ‘Shorty’ is shipped with the burner and controls separate from the boiler.

Description

The Kingston (KSZ) Series boiler is an installer-ready, residential, cast-iron, oil-fired, steam boiler. The Kingston is designed for installation with a standard chimney. The Kingston is available in heating capacities from 79 to 235 MBH. This boiler is available in a semi-packaged ‘Shorty’ version. The ‘Shorty’ is shipped with the burner and controls separate from the boiler.

Options on the KSZ series include a domestic coil and your choice of three different oil burners: Beckett (standard), Riello or Carlin. Features of the KSZ series include a wet-base heat exchanger design, cast-iron burner swing door, a 3-prong quick disconnect for easy service and a barometric damper. Some models of the KSZ are ENERGY STAR® qualified. See the Product Ratings tab for details.

Optional Equipment

Crown Boiler Steam Piping KitThe Kingston KSZ Series boiler is compatible with our Steam Boiler Piping Kit, a more convenient way to pipe steam boilers. For more information on the Steam Boiler Piping Kit, visit the Steam Boiler Piping Kit page.

 

Download Brochure

Kingston_Literature1

 

Product Brief

 

Type:Residential
Heat Exchanger:Cast Iron
Fuel:Oil
Input:0.65 – 2.00 GPH
Efficiency (AFUE)82.9% – 85.4%
Venting:Chimney
Ignition:N/A
Trim:Steam
Domestic Water:Optional – Tankless Coil
Burner:Becket, Carlin or Riello
Configuration:Packaged and Shorty
Notes:Some models are ENERGY STAR qualified. See Product Ratings tab for details.

 

 

Product Ratings

 

MODEL NUMBERNO. SECTIONSHEATING CAPACITY
(MBH)
AHRI NET
RATING
(MBH)
AHRI NET
RATING
SQ. FT.
BURNER CAPACITY
GPH
AFUE
(%)
TANKLESS HEATER
GPM
CHIMNEY SIZE
IN. x IN. x FT.
APPROX SHIPPING
WEIGHT
(LBS)
KSZ065*379592460.6585.12.258 x 8 x 15570
KSZ075390682830.7584.52.258 x 8 x 15570
KSZ1003119893701.0083.52.508 x 8 x 15570
KSZ090*4110833460.9085.02.508 x 8 x 15690
KSZ12541491124671.2584.22.758 x 8 x 15690
KSZ15041771335541.5083.13.008 x 8 x 15690
KSZ120*51471104581.2085.42.758 x 8 x 15810
KSZ17552071556461.7583.13.258 x 8 x 15810
KSZ20052351767332.0082.93.508 x 8 x 15810
  1. Altitudes above 2,000 ft. – ratings should be reduced at a rate of 4% for each 1,000 ft. above sea level (U.S.A only).
  2. The Net Steam Ratings shown are based on a piping and pickup allowance of 1.33.
  3. Burner Input Rating, GPH is based on #2 oil with a Gross Heating Valve equal to 140 MBH.
  4. Minimum recommended chimney size is 8″x 8″x 15′.
  5. The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc.

 

 

Product Dimensions

 

MODEL NUMBERDIMENSION (INCHES)FLUE COLLAR DIAMETER
(INCHES)
AB
KSZ06517-3/88 – 5/66
KSZ07517-3/88 – 5/66
KSZ10017-3/88 – 5/66
KSZ09022-3/810-13/167
KSZ12522-3/810-13/167
KSZ15022-3/810-13/167
KSZ12027-3/813 – 5/168
KSZ17527-3/813 – 5/168
KSZ20027-3/813 – 5/168

KSZ-CONFIGURATION

 

Related Documents

 

kingston_near_boiler_piping_schematic

kingston_troubleshooting

Kingston_KSZ_Installation_Manual-1

Kingston_Literature1

kingston_nomenclature

 

Reviews

There are no reviews yet.

Be the first to review “Kingston (KSZ)”