Freeport 2 (FSZ)

The Freeport 2 FSZ Series boiler is a 3-pass cast-iron, oil-fired, steam boiler. The Freeport 2 FSZ is designed for installation with a standard chimney. This boiler is available in heating capacities from 97 to 195 MBH. See the product ratings tab for more details.

 

Description

The Freeport 2 FSZ Series boiler is a 3-pass cast-iron, oil-fired, steam boiler. The Freeport 2 FSZ is designed for installation with a standard chimney. This boiler is available in heating capacities from 97 to 195 MBH. See the product ratings tab for more details.

The Freeport 2 FSZ features a swing door with burner disconnect plug for easy access to all heating surfaces on the front of the boiler. A Beckett AFG or Riello burner are packaged separately for easier handling. The boiler comes standard with an A.S.M.E. 15 PSI safety valve, pressure gauge, barometric damper, probe low water cutoff, and pressure limit. A side-mounted tankless coil for domestic hot water is optional, while the boiler comes with tappings in the back to work with an indirect water heater like the Mega-Stor®. Near boiler piping kits are available separately for ease of installation.

Optional Equipment

Crown Boiler Steam Piping Kit The Freeport 2 FSZ Series boiler is compatible with our Steam Boiler Piping Kit, a more convenient way to pipe steam boilers. For more information on the Steam Boiler Piping Kit, visit the Steam Boiler Piping Kit page.

 

Download Brochure

Freeport_2_FSZ_Literature

 

Product Brief

 

Type: Residential/Light Commercial
Heat Exchanger: Cast Iron
Fuel: Oil
Input: 0.80 – 1.60 GPH
Efficiency (AFUE) 85.7% – 86.0%
Venting: Chimney
Ignition: N/A
Trim: Steam
Domestic Water: Optional – Tankless Coil
Burner: Beckett/Riello
Configuration: Semi-packed
Notes: 3 Pass Design

 

Product Ratings

 

MODEL NUMBER BURNER INPUT HEATING CAPACITY
(MBH)
AHRI NET
RATINGS
AFUE % WATER CONTENT
(GAL)
HEAT TRANSER
SURFACE AREA
(SQ FT)
SHIPPING WEIGHT
(LBS)
GPH MBH MBH SQ. FT. W/ TANKLESS
HEATER
NON-HEATER
FSZ080 0.80 112 97 73 303 85.7 15.3 14.9 20.29 607
FSZ100 1.00 140 122 92 381 86.0 15.3 14.9 20.29 607
FSZ130 1.30 182 158 119 494 86.0 19.7 19.3 27.29 744
FSZ160 1.60 224 195 146 610 85.9 24.1 23.8 34.29 881
  1. Burner capacity rating, GPH, is based on #2 fuel oil with a Gross Heating Value equal to 140,000 BTU/gal.
  2. Net Ratings are based on a piping and pickup allowance of 1.333.
  3. Maximum working pressure, steam – 15 PSI.

 

 

Product Dimensions

 

MODEL NUMBER DIMENSION (INCHES)
“A” “B” “C”
FSZ080 22 – 1/4 24 6
FSZ100 22 – 1/4 24 6
FSZ130 28 – 1/4 30 6
FSZ160 34 – 1/4 36 7

FsZ Spec drawing

 